CONTEC CMS7000 Multi-Parameter Medical Patient Monitor for ICU/ Hospital/ Clinics with CE/ FDA



 




Functions


 



Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP

This medical patient monitor has other abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc.



 




Features


 



1- 12.1'' TFT color LCD, 15-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakhstan, Polish, Czech).

2- Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.

3- All-round medical patient monitor for adult, pediatric and neonates.

4- With the standard interface, OxyCRG, trend chard, big character interface and view bed, convenient to observe.

5- Waveform, parameter color and location can be set optionally.

6- Operation mode: keys and buttons.

7- Display up to 8-channel waveform on one screen.

8- Display 7-lead ECG waveform on one screen, and with ECG step function.

9- Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.

10- HRV analysis function.

11- NIBP measurement mode-Manual/AUTO/Continuous, storage for 4800-group NIBP data.

12- Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.

13- Drug concentration calculation and titration table functions.

14- Print trend table data with one key.

15- Connect to Central Monitoring System by 3G, WiFi, or wired mode.

16- AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.

17- Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary).



 




Performance


 



â—‹ ECG








































































Lead mode



3-lead or 5-lead



Lead selection



I, II, III, aVR, aVL, aVF, V



Waveform



5-lead, 2-channel



3-lead, 1-channel



Gain



2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV



Scan speed



12.5mm/s, 25 mm/s, 50 mm/s



HR



Measurement and alarm range



15~350bpm



Accuracy



±1% or ±1bpm, whichever is greater



Alarm accuracy



± 2 bpm



Resolution



1 bpm



ST-segment monitoring



Measurement and alarm range



-2.0mV~+2.0mV



Accuracy



-0.8mv~+0.8mv ±0.04mv or ±10%, whichever is greater



Other range



Unspecified



Arrhythmia analysis



ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC



Pacemaker



yes




 



â—‹ RESPIRATION






































Method



R-F(RA-LL) Impedance



Respiration rate



Measurement and alarm range



0~150rpm



Resolution



1 rpm



Measurement accuracy



±2 rpm



Alarm accuracy



±3 rpm



Apnea alarm



10~40s



Scan speed



6.25 mm/s, 12.5 mm/s, 25 mm/s




 



â—‹ NIBP





























































Method



Oscillometry



Mode



Manual/AUTO/Continuous



Measurement interval in AUTO mode



1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes



Measurement period in Continuous mode



5 minutes



Measurement and alarm range



10 ~ 270 mmHg



Resolution



1 mmHg



Cuff pressure accuracy



±3 mmHg



Measurement accuracy



Maximal mean deviation



±5 mmHg



Maximal standard deviation



8mmHg



Over-pressure protection



Adult mode



297±3 mmHg



Pediatric mode



240±3 mmHg



Neonatal mode



147±3 mmHg




 



â—‹ SpO2






















Measurement and alarm range



0 ~ 100%



Resolution



1%



Measurement accuracy



70%~100%: ±2%



0%~69%: unspecified




 



â—‹ PR















Measurement and alarm range



30 ~ 250 bpm



Measurement accuracy



±2 bpm or ±2%, whichever is greater




 



â—‹ TEMP























Channel



Dual-channel



Measurement and alarm range



0 ~ 50℃



Resolution



0.1 ℃



Accuracy



±0.1 ℃




 



â—‹ EtCO2















































Method



Sidestream or Mainstream



Measurement range for CO2



0~150mmHg



Resolution for CO2



0 ~ 69 mmHg: 0.1 mmHg



70 ~ 150 mmHg: 0.25 mmHg



Accuracy for CO2



0 ~ 40 mmHg: ±2 mmHg



41 ~ 70 mmHg: ±5%



71 ~ 100 mmHg: ±8%



101 ~ 150 mmHg: ±10%



AwRR range



2~150 rpm



AwRR accuracy



±1 rpm



Apnea alarm



Yes




 



â—‹ IBP



































Channel



Dual-channel



Label



ART, PA, CVP, RAP, LAP, ICP, P1, P2



Measurement and alarm range



-10~300 mmHg



Resolution



1 mmHg



Accuracy



±2% or 1mmHg, whichever is greater



Power supply



AC 100-240V, 50/60Hz



Safety classification



Class I, type CF defibrillation-proof applied part




 




Accessories


 



● Adult fingertip SpO2 probe (5-pin);

● Adult NIBP cuff;

● NIBP extension tube;

● ECG lead cable;

● ECG electrode;

● Temperature probe;

● Power cord;

● User Manual.



● Physical characteristic: 319 mm(L) × 161 mm(W) × 269 mm(H); Weight: 3.6 Kg.



 