TitleProduct

Energy Saving 2 Pipe Ceiling Mounted Floor Standing Fan Coil Unit

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Guangdong

  • Validity to:

    Long-term effective

  • Last update:

    2017-07-05 22:01

  • Browse the number:

    144

Send an inquiries

Company Profile

Shenzhen Eurostars Technology Co., Ltd.

By certification [File Integrity]

Contact:Mr. John(Mr.)  

Email:

Telephone:

Phone:

Area:Guangdong

Address:Guangdong

Website: http://eurostarschiller.jstianchuang.com/

Product Details


Energy Saving 2 Pipe Ceiling Mounted Floor Standing Fan Coil Unit

1. Ceiling floor fan coil features:
(1)Low noise; (2) High efficient and energy saving; (3) Strong air flow; (4) Flexible installation; (5) Easy operation.

In central air conditioner system, Eurostars ceiling exposed floor standing fan coil continuously exchanges the indoor air with cool & heat supplied by chiller system, in order to adjust the room temperature and humidity. Ceiling floor fan coil is widely appliated in bureaux, business building, superstore, hotel, hospital, bank, apartment and amusement place.


2. Ceiling floor fan coil unit nomenclature

ES T 500 CF2 T R A O
1 2 3 4 5 6 7 8
1: ES Eurostars
2 :T Terminal series
3 :500 Rated air flow: CFM
4 :CF2 Ceiling exposed floor mounted and the number of tube system
5 :T Coil type: T-2C0H (Note: C-Cold water coil; H-Hot water coil)
6 :R Connection pipe direction: R-Right (face to air outlet) L-Left (face to air outlet)
7: A Power supply: A-220V-50HZ; K-208~230V-60HZ; N-115-60HZ; W-265~277V-60HZ
8 :O Sales region: O-Other regions; C-Mainland China

3.Ceiling floor fan coil techinal specification
Please ask salesman for detailed complete data or visit our website:
www.eurostarschina.com

Ceiling Exposed/Floor Mounted Fan Coil Unit (2 pipe system)
Model EST~ 300CF2 400CF2 500CF2 600CF2 800CF2 1000CF2 1200CF2 1400CF2
Air flow
 (m3/h)
High  510 680 850 1020 1360 1700 2040 2380
Medium 420 560 770 910 1210 1450 1850 2150
Low  340 480 610 820 1100 1380 1600 2000
Cooling capacity TH H W 2700 3600 4500 5400 7200 9000 10800 12600
BTU 9215 12287 15359 18430 24574 30717 36860 43004
SH W 1990 2730 3174 4261 5385 6746 8109 9062
BTU 6792 9317 10833 14543 18379 23024 27676 30929
TH M W 2485 3030 3752 4467 6499 7926 9389 10605
BTU 8481 10341 12806 15246 22181 27051 32045 36195
SH W 1570 2015 2450 3070 4278 5447 6669 7262
BTU 5358 6877 8362 10478 14601 18591 22761 24785
TH L W 2078 2504 2950 3831 5660 7295 8619 8989
BTU 7092 8546 10068 13075 19318 24898 29417 30679
SH W 1212 1545 1844 2397 3317 4460 5300 5555
BTU 4137 5273 6294 8181 11321 15222 18089 18959
Heating capacity H W 4050 5400 6750 8100 10800 13500 16200 18900
BTU/h 13823  18430  23038  27645  36860  46076  55291  64506 
M W 2792 3970 4941 5740 7987 10557 13101 14011
BTU/h 9529  13550  16864  19591  27260  36031  44714  47820 
L W 1788 2800 3533 3907 5464 7048 8714 9778
BTU/h 6102  9556  12058  13335  18649  24055  29741  33372 
Power Input H W 52 62 76 96 134 152 189 228
Noise H dB(A) 39.00  41.00  43.00  45.00  46.00  48.00  50.00  51.00 
Water Flow m3/h 0.46  0.62  0.77  0.93  1.23  1.54  1.85  2.16
Water resistance  kPa 11.80  13.60  21.00  23.00  25.00  32.00  33.00  38.00 
Heat Exchanger  Type copper tubes with shutter-type hyperbolic aluminum fins
Working pressure 1.6MPa
Testing pressure Airtightness test under pressurized water:3.3MPa
Motor Type Single-phase capacitive motor equips with fine ball bearing, low noise,long service life
Power supply 220V-/50HZ
Protection grade IP20
Insulation grade B
Pipe  Inlet/outlet water pipe Rc 3/4 " internal thread
Condensation water pipe ¢26
N.W. Kg 31 31 31 41 41 46 46 46

Note:
(1)Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2)Heating: Inlet air temperature DB 21°C, heating water inlet temperature 60°C (tested by the same water flow with cooling condition).
(3)The noise level is measured in: background noise 11.5Db(A) semi-anechoic room as per GB/T19232-2003.
(4)Rated air flow is tested in standard air condition with DB 20ºC.
(5)Specifications are subject to product improvement and change without notice.

4.Ceiling floor fan coil unit product views


5.Ceiling floor fan coil unit installation illustration



6. Eurostars fan coil unit series
((1)Wall mounted split fan coil unit
(2)Ceiling floor fan coil unit
(3)Horizontal concealed ceiling duct fan coil unit
(4)Horizontal exposed fan coil unit
(5)Ceiling cassette fan coil unit
(6)Vertical exposed fan coil unit
(7)Vertical concealed fan coil unit